Battery Test and Simulation System II

Application

  • characterisation of energy storages including a cooling system under varying climatic conditions
  • development and testing of cooling systems and thermal management systems
  • development and testing of battery management systems
  • simulation of energy storage systems based on Matlab/Simulink models

Technical Data Battery Tester

  • voltage range: 10 – 1000 V
  • current range: ± 1000 A
  • maximum power: ± 400 kW
  • dynamics (load step 10 – 90 %): 1 ms
  • interface to Matlab/Simulink
  • rest bus simulation

Technical Data Climatic Chamber

  • inner dimensions (w/d/h): 2 m x 2.50 m x 2.20 m
  • temperature range: -40 to 70°C
  • humidity range: 10 – 95 % rel. humidity
  • dew point range: 5 – 68.8 °C
  • dynamics: 2 K/min
  • testing up to hazard level 6 possible

Contact

Dr.-Ing. Damian Backes
Head of Energy Management and Drivetrains
+49 241 80-25420
Email